Hanna-instruments HI 86301 User Manual

Browse online or download User Manual for Sensors Hanna-instruments HI 86301. Hanna Instruments HI 86301 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
WARRANTY
These instruments are guaranteed for two years against
defects in workmanship and materials when used for their
intended purpose and maintained according to instructions.
Probes are guaranteed for six months. This warranty is
limited to repair or replacement free of charge. Damages due to
accidents, misuse, tampering or lack of prescribed maintenance
are not covered. If service is required, contact the dealer from
whom you purchased the instrument. If under warranty, report
the model number, date of purchase, serial number and the
nature of the failure. If the repair is not covered by the
warranty, you will be notified of the charges incurred. If the
instrument is to be returned to Hanna Instruments, first obtain
a Returned Goods Authorization Number from the Customer
Service department and then send it with shipment costs
prepaid. When shipping any instrument, make sure it is
properly packaged for complete protection.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna Instruments.
Dear Customer,
Thank you for choosing a Hanna product.
Please read carefully this instruction manual before using the
meter. If you need additional technical information, do not
hesitate to e-mail us at [email protected].
These instruments are in compliance with the directives.
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine
it carefully. If any damage has occurred during shipment,
immediately notify your Dealer or the nearest Hanna Customer
Service Center.
Each meter is supplied with:
Conductivity probe
HI 7634D/1 for HI 86301 and HI 86303
HI 7632D/1 for HI 86302 and HI 86304
Calibration solution sachet (20 mL)
HI 70031 (1413 μS/cm) for HI 86303
HI 70039 (5.00 mS/cm) for HI 86304
HI 70032 (1382 ppm) for HI 86301 & HI 86302
Battery, screwdriver & instructions
Note: Conserve all packing material until the instrument has
been observed to function correctly. Any defective item
must be returned in its original packing.
GENERAL DESCRIPTION
These EC and TDS portable meters have been designed for
simplicity of use, and provide accurate measurements.
Readings are automatically compensated for temperature varia-
tions, and the calibration is manually performed at one point
through trimmer.
The BEPS (Battery Error Prevention System) automatically
switches the meter off when the battery level is too low to
ensure reliable readings.
The housing has been completely sealed against humidity, for
use in any type of environment.
The probe is easy to clean and requires little maintenance.
Choose the model with the measurement range that best fits
your application:
HI 86301 reads TDS from 0 to 1999 ppm (mg/L)
HI 86302 reads TDS from 0.00 to 10.00 ppt (g/L)
HI 86303 reads EC from 0 to 1999 μS/cm
HI 86304 reads EC from 0.00 to 19.99 mS/cm
SPECIFICATIONS
Hanna Instruments reserves the right to modify the design,
construction and appearance of its products without advance notice.
EC Models
HI 86303 HI 86304
Range 0 to 1999 μS/cm 0.00 to 19.99 mS/cm
Resolution 1 μS/cm 0.01 mS/cm
Accuracy ±2% f.s
Calibration Manual, 1 point,
through trimmer in the battery compartment
Probe (included) HI 7634D/1 HI 7632D/1
Temp.Compensation Automatic, 0 to 50°C (32 to 122°F)
with β=2%/°C
Environment 0 to 50 °C (32 to 122°F); RH max 100%
Battery Type 1 x 9V alkaline
Battery Life Approx. 300 hours Approx. 150 hours
Dimensions 164 x 76 x 45 mm (6.4 x 3.0 x 1.8’’)
Weight 250 g (8.8 oz.)
TDS Models
HI 86301 HI 86302
Range 0 to 1999 ppm 0.00 to 10.00 ppt
Resolution 1 ppm 0.01 ppt
Accuracy ±2% f.s
Calibration Manual, 1 point,
through trimmer in the battery compartment
Probe (included) HI 7634D/1 HI 7632D/1
Temp.Compensation Automatic, 0 to 50°C (32 to 122°F)
with β=2%/°C
Environment 0 to 50 °C (32 to 122°F); RH max 100%
Battery Type 1 x 9V alkaline
Battery Life Approx. 300 hours Approx. 150 hours
Dimensions 164 x 76 x 45 mm (6.4 x 3.0 x 1.8’’)
Weight 250 g (8.8 oz.)
www.hannainst.com
Instruction Manual
HI 86301 • HI 86302
HI 86303 • HI 86304
TDS and EC Meters
Page view 0
1 2

Summary of Contents

Page 1 - TDS and EC Meters

WARRANTYThese instruments are guaranteed for two years againstdefects in workmanship and materials when used for theirintended purpose and maintained

Page 2 - IST86301 05/05

ACCESSORIESHI 7632D/1 Conductivity probe, HR, with built-in tempera-ture sensor, DIN connector and 1 m (3.3’) cableHI 7634D/1 Conductivity probe, LR,

Related models: HI 86302 | HI 86304 |

Comments to this Manuals

No comments