188
Instruction Manual
HI 93703-11
Portable Logging
Turbidity Meter with RS232
www.hannainst.com
MAN93703-11R1 08/05
SALES AND TECHNICAL SERVICE CONTACTS
Australia:
Tel. (03) 9769.0666 • Fax (03) 9769.0699
China:
Tel. (10) 88570068 • Fax (10) 88570060
Egypt:
Tel. & Fax (02) 2758.683
Germany:
Tel. (07851) 9129-0 • Fax (07851) 9129-99
Greece:
Tel. (210) 823.5192 • Fax (210) 884.0210
Indonesia:
Tel. (21) 4584.2941 • Fax (21) 4584.2942
Japan:
Tel. (03) 3258.9565 • Fax (03) 3258.9567
Korea:
Tel. (02) 2278.5147 • Fax (02) 2264.1729
Malaysia:
Tel. (603) 5638.9940 • Fax (603) 5638.9829
Singapore:
Tel. 6296.7118 • Fax 6291.6906
South Africa:
Tel. (011) 615.6076 • Fax (011) 615.8582
Taiwan:
Tel. 886.2.2739.3014 • Fax 886.2.2739.2983
Thailand:
Tel. 66.2619.0708 • Fax 66.2619.0061
United Kingdom:
Tel. (01525) 850.855 • Fax (01525) 853.668
USA:
Tel. (401) 765.7500 • Fax (401) 765.7575
For e-mail contacts and complete list of Sales and
Technical offices, please see www.hannainst.com
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - HI 93703-11

LOGLOBATTIMEDATELOGGINGMICROPROCESSORTURBIDITYMETERLOGGINGMICROPROCESSORTURBIDITYMETERALTDATEREADVIEWSTOCLRCALGLPOFFONHI93703-11HI93703-11%188Instruct

Page 2

10* 1 FTU = 1 NTU• Even though HI93703-11 covers a verywide range of turbidity values, for veryaccurate measurements of samples ex-ceeding 40FTU*, Sta

Page 3 - * 1 FTU = 1 NTU

11LOG-ON-DEMAND:• After taking a read-ing, press the STObutton. The lastsample read will bestored in memory.The display will alsoshow on the bottomrig

Page 4

12VIEWING LOGGED DATA:• Press the ALT & VIEWbuttons together. Thelast sample will be dis-played.• Press the right arrow toscroll between turbidity

Page 5 - DETECTOR

2Dear Customer,Thank you for choosing a Hanna product.Please read this instruction manual carefullybefore using the instrument.This manual will provid

Page 6 - STANDARD SUSPENSION

3Remove the instrument from the packing materialand examine it to make sure that no damage hasoccurred during shipping. If there is any damage,notify

Page 7 - ENSURE ACCURATE CALIBRATION

4The meter is housed in a rugged and lightweightcase, with an easy-to-read LCD.To save battery-life, the instrument is equippedwith an automatic shut-

Page 8 - MEASUREMENT PROCEDURE:

5IR LEDEMITTED LIGHT (890 nm)CUVETLIGHTDETECTOR90° SCATTEREDLIGHTPRINCIPLE OF OPERATION* 1 FTU = 1 NTUHI 93703-11 has been designed to performmeasurem

Page 9 - CALIBRATION PROCEDURE

63516784LOG LOBATTIMEDATELOGGINGMICROPROCESSORTURBIDITYMETERLOGGINGMICROPROCESSORTURBIDITYMETERHI 93703-11VIEWVIEWSTOSTOCLRCLRGLPGLPCALCALDATEDATEREAD

Page 10 - SOURCES OF INTERFERENCE

7SPECIFICATIONS* 1 FTU = 1 NTURange 0.00 to 50.00 FTU *50 to 1000 FTU *Resolution 0.01 and 1 FTU *Accuracy ±0.5 FTU* or±5% of reading (whichever is gr

Page 11 - ENSURE ACCURATE MEASUREMENTS

8To prepare the instrument for takingmeasurements, first install the batteries (seeBattery Replacement section on page 20) andthen turn the instrument

Page 12 - ERROR CODES:

9NOTE: Wipe the cuvet thoroughly with a lint-free tissue (HI93703-70) before in-serting into the measurement cell.The cuvet must be completely free of